ECoclean Technology Sdn Bhd, Malaysian Licensee for CDS technology
Home | About us | Technology | Awards | Projects | Downloads | Links | Contact us |


Project Profile

Putrajaya View
Bandar Botanic Parcel A, Klang, Selangor View
Kuala Lipis Teachers’ Quarters Project, Pahang View
Bandar Raub, Pahang View
Sg. Sekilau, Pahang View
USJ School, Selangor View
Glenmarie Cove, Klang, Selangor View
Shah Alam 2, Shah Alam, Selangor View
Apartment Pelajar Uniten, Selangor View
University of Nottingham, Selangor View
Waller Court Apartments, Ipoh, Perak View
Precinct 14-7, Putrajaya View

Putrajaya

 Location of CDS units
Precint 3 & 4, Putrajaya.

Client Requirement
Putrajaya Holding emphasizes the preservation of its eco-system. Surrounding by lakes, the development of Putrajaya must provide a defense for the lake and most effective in trapping the pollutants. CDS units were selected by being aesthetically appealing.

Application
Stormwater pollution control trap

Emptying method
Vacuum suction truck

Size of CDS unit
Ranges from P1009 to P1015 with 32 units installed.

 

Putrajaya

 

 

Putrajaya

 


Top

Bandar Botanic Parcel A, Klang, Selangor

 Location of CDS units
Bandar Botanic, Kelang, Selangor..

Client Requirement
The Bandar Botanic development emphasizes on the serenity of its surrounding. There are several man-made lakes around the development with 18 drainage outlet to the lake in phase 1 itself.

Application
Stormwater pollution control trap

Catchment Area
In total there are 18 unit with catchment area ranging from 3.14 ha to 19.1 ha.

Design flow treated and ARI event equivalent
From 0.04 to 0.75 cumecs

Emptying method
Litter basket.

Size of CDS unit
Twin unit F0908 and 17 single units of F0908 and F0912

 

Bandar Botanic Parcel A, Klang, Selangor

 

 

Bandar Botanic Parcel A, Klang, Selangor

 


Top

Kuala Lipis Teachers’ Quarters Project, Pahang

 Location of CDS units
Kuala Lipis Teachers’ Quarters
Pahang..


Client Requirement
The client requires a gross pollutant trap that is easy to maintain. This is essential as the site being rural area, does not have the facility of a vacuum truck.

Application
Stormwater pollution control trap

Catchment Area
10 ha

Design flow treated and ARI event equivalent
3 m³/s


Emptying method
Litter basket. System comes with lifting hoist with monorail.

Size of CDS unit
Twin unit F0908


 

Kuala Lipis Teachers’ Quarters Project, Pahang

 

 

Kuala Lipis Teachers’ Quarters Project, Pahang

 

 

Access ladder going down to the CDS unit for inspection
Access ladder going down to the CDS unit for inspection

 

Top

Bandar Raub, Pahang

No information available at the moment

 

Sg. Sekilau, Pahang

Location of CDS units
Sungai Sekilau, Kuantan, Pahang

Client Requirement
A pioneer project by the Drainage And Irrigation Department to control pollutant from Sungai Sekilau. Due to unavailability of vacuum truck, CDS offers the only alternative to an easy and cost effective maintenance using lifting basket method for quick removal of trapped pollutant.

Application
Stormwater pollution control trap

Catchment Area
Creek / Small river.

Design flow treated and ARI event equivalent
3 m³/s


Emptying method
Litter basket.


Size of CDS unit
P1512

 

Sg. Sekilau, Pahang

 

 

Sg. Sekilau, Pahang

 


Top

USJ School, Selangor

No information available at the moment

 Top

Glenmarie Cove, Klang, Selangor

Location of CDS Unit
By the lake next to new club house of a very exclusive development

Client Requirement
To control and minimize sediment and pollutant discharge into the lake from adjacent main road and park activity areas

Application
Stormwater pollutant control trap

Catchment
1 ha

Design Flow Treated and ARI Event Equivalent
0.02 m3/s

Capturing Method
Litter basket

CDS Model
F0908


 

 

 

 

 

 

 

 

Top

Shah Alam 2, Shah Alam, Selangor

Location of CDS Unit
Outlet discharging to next water source

Client Requirement
To remove at least 95% gross pollutant before discharging to lake and must be constructed within a 12 meter right of way

Application
Stormwater pollutant control trap

Catchment
175 ha

Design Flow Treated and ARI Event Equivalent
2.5 m3/s

Capturing Method
Litter basket

CDS Model
P2028


 

 

 

 

Top

Apartment Pelajar Uniten, Selangor

Location of CDS Unit
UNITEN, Jalan Serdang, Kajang, Selangor Darul Ehsan

Client Requirement
To remove all gross pollutant before discharge into onsite detention tank. The stormwater runoff use being harvested and treated is re-use for irrigation

Application
Stormwater pollutant control trap

Catchment
1.8 ha

Design Flow Treated and ARI Event Equivalent
0.306 m3/s

Capturing Method
Litter basket

CDS Model
2 no. P1015


 

 

 

 

 

 

Top

University of Nottingham, Selangor

Location of CDS Unit
University of Nottingham, Semenyih, Selangor Darul Ehsan.

Client Requirement
This University campus would like to create a harmony and natural environment around the campus with a man-make lake located at the centre of the campus with 3 drainage outlets to the lake.

Application
Stormwater pollutant control trap

Catchment
12.43 ha

Design Flow Treated and ARI Event Equivalent
From 0.24 m3/s - 0.98 m3/s

Capturing Method
Litter basket

CDS Model
2 x P1015 and P2018


 

 

 

 

 

 

 

 

Top

Waller Court Apartments, Ipoh, Perak

Location of CDS Unit
Outlet discharging to Sungai Kinta.

Client Requirement
To control and minimize sediments and pollutants discharged into Sungai Kinta from the adjacent residential areas.

Application
Stormwater pollution control trap

Catchment
4.84 ha

Design Flow Treated and ARI Event Equivalent
0.51 m3/s

Capturing Method
Litter basket

CDS Model
P1009

 

 

 

 

Top

Precinct 14-7, Putrajaya

Location of CDS Unit
Outlet discharging to the retention pond.

Client Requirement
Putrajaya Holding emphasizes the preservation of its eco-system. Surrounded by lakes, the development of Putrajaya must provide a defense for the lake and most effective solution in trapping the pollutants. CDS units were selected also due to being aesthetically appealing.

Application
Stormwater pollution control trap

Catchment
28 ha

Design Flow Treated and ARI Event Equivalent
3.3 m3/s

Capturing Method
Vacuum Suction Tank

CDS Model
P2028

 

 

 

 

 

 

Top

 
Previous Page
Next Page
   
   
Copyright 2003 EcoClean Technology Sdn Bhd Staff email